Spherical bearing vertical bearing capacity testing is an essential laboratory verification procedure that confirms whether spherical bridge bearings can safely sustain their rated design loads without excessive deformation or structural damage. This test is a mandatory requirement under international standards such as GB/T 17955 and the EN 1337 series, and is widely performed by accredited third-party laboratories for type approval, factory acceptance, and in-service evaluation. In this article, we explain the purpose, sample requirements, test items, methods, and acceptance criteria of the spherical bearing vertical bearing capacity test.
Technical Overview
A spherical bearing is a structural bearing type commonly installed between bridge superstructures and substructures. It typically consists of an upper sole plate, a convex spherical cap, a concave seat, polytetrafluoroethylene (PTFE) sliding sheets, stainless steel sliding surfaces, a base plate, and an anchoring system. The spherical sliding interface allows rotation about any horizontal axis, while the planar sliding interface accommodates longitudinal and transverse translation, making this bearing type especially suitable for curved bridges, wide bridges, long-span bridges, and railway structures.
The vertical bearing capacity test is designed to verify that the bearing can carry its rated vertical design load, and a defined overload multiple of that load, without exhibiting unacceptable compression deformation, local failure of the PTFE sliding material, cracking of steel components, leakage of the internal silicone grease lubricant, or significant residual deformation after unloading. The test is governed primarily by GB/T 17955 for spherical bridge bearings and by the EN 1337 series, particularly EN 1337-7 for spherical and cylindrical bearings with PTFE sliding surfaces, supplemented by EN 1337-2 for sliding element requirements.
- Verification of structural safety under rated and overload conditions
- Measurement of vertical compressive deformation characteristics
- Confirmation of PTFE sliding material performance under sustained compressive stress
- Provision of objective evidence for type approval, factory acceptance, and quality certification
Testing Samples
Prototype Samples for Type Testing
Type tests are performed on full-scale prototype bearings representing a new design or a design family. The prototype must be manufactured with the same materials, dimensions, tolerances, welding procedures, and sliding surface configurations as the production bearings it represents. Testing at an overload multiple of the design load demonstrates the margin of safety of the complete design before mass production begins.
Production Samples for Acceptance Testing
For routine acceptance testing, finished bearings are randomly selected from each production batch according to the sampling rules of the applicable standard. These samples are tested to verify that routine manufacturing quality remains consistent with the approved type-tested design. Selection is typically based on bearing capacity class, with the most heavily loaded configuration in a family prioritized for verification.
Sample Preparation and Conditioning
Before testing, samples are inspected for dimensional compliance, surface finish of the stainless steel sheets, PTFE sheet recess depth, and completeness of assembly. Bearings are conditioned in the laboratory at ambient temperature, typically 23 ± 5 °C, to ensure that material properties, particularly those of the PTFE and elastomeric components, are evaluated under standardized thermal conditions. All identification information, including rated capacity, displacement rating, and serial number, is recorded before the specimen is installed in the loading frame.
Testing Items
The vertical bearing capacity test comprises several measured and observed evaluation items, which together determine whether the bearing passes or fails.
- Vertical compressive deformation at rated design load and at the specified overload factor
- Ultimate load-holding performance under the maximum test load
- Verification that the average compressive stress on the PTFE sliding sheets remains within the permissible limit, typically capped at 30 MPa under service conditions, with short-term allowances defined by the governing standard
- Residual (permanent) deformation measured after complete unloading
- Structural integrity of steel components, including absence of cracks, yielding, weld defects, or visible distortion
- Condition of the PTFE sheets, including absence of cold flow, extrusion beyond the retaining recess, blistering, or delamination
- Sealing performance, verified by absence of silicone grease leakage at the sliding interfaces and dust seals
- Uniformity of deformation around the bearing perimeter, as an indicator of concentric loading and absence of harmful eccentricity
Testing Methods
Test Apparatus and Setup
The test is performed using a calibrated compression testing machine or a self-balancing reaction frame equipped with a hydraulic actuator. The machine capacity must comfortably exceed the maximum test load, and its force measurement system must be calibrated with traceability to national standards, with an accuracy of ±1% or better. Rigid distribution plates are placed above and below the specimen to ensure uniform load application. The bearing is carefully centered beneath the loading axis using the manufacturer's center marks, since eccentric loading can distort deformation results and trigger premature localized failure.
Preloading and Seating Procedure
Before recording data, the bearing is subjected to one or more preload cycles up to the design vertical load and then unloaded. This seating procedure eliminates initial clearances, settles the sliding interfaces, and stabilizes the load-deformation response. Readings taken after the final preload cycle establish the baseline for measurement.
Incremental Loading to the Overload Level
The vertical load is then applied in controlled increments, commonly in steps of 25% of the design load, until the specified maximum test load is reached. Depending on the applicable standard and the test classification, the maximum test load is typically between 1.5 and 2.0 times the rated vertical design load. At each increment, load and deformation readings are recorded after the load stabilizes. The maximum test load is then held constant for a defined holding period, typically not less than three minutes or until deformation readings have stabilized, during which the specimen is continuously monitored. Finally, the load is removed in controlled decrements and residual deformation is measured.
Instrumentation and Data Acquisition
Vertical deformation is measured with a minimum of four displacement transducers or dial gauges with a resolution of 0.01 mm, positioned at 90-degree intervals around the bearing perimeter. The average of the four readings gives the true vertical compression, while differences between individual readings reveal any tilting or non-uniform deformation. A calibrated load cell or the machine's certified force measurement system records the applied load throughout the test, and a data acquisition system generates the continuous load-deformation curve. Protective shielding is installed around the loading frame during overload stages as a safety precaution.
Acceptance Criteria
The bearing is considered to have passed the vertical bearing capacity test when the load-deformation behavior remains essentially linear or within the design envelope, the vertical compressive deformation at the design load does not exceed the limit specified in the applicable standard, the deformation under the overload is stable without progressive increase during the holding period, and the residual deformation after unloading is within the permitted tolerance. In addition, visual inspection must confirm the absence of cracks in any steel component, no yielding or permanent distortion of plates, no extrusion or damage of the PTFE sheets, and no leakage of lubricating grease. Any deviation from these criteria constitutes a failure requiring root-cause analysis and corrective action.
Applications
Vertical bearing capacity testing of spherical bearings is applied throughout the life cycle of bridge and structural bearing products, serving multiple engineering and regulatory purposes.
- Type approval and certification of new spherical bearing designs prior to production
- Factory acceptance testing and batch release for highway and railway bridge projects
- Independent verification testing commissioned by project owners, designers, and contractors at accredited third-party laboratories
- Qualification of bearings for demanding installations, including long-span cable-stayed and suspension bridges, curved and skewed bridges, and high-speed railway bridges
- Assessment of in-service bearings recovered from structures during rehabilitation, replacement, or forensic investigation
- Research and development support for improved PTFE composites, sliding surface treatments, and seismic-resistant bearing configurations
Beyond bridges, spherical bearings are also used in large-span steel roof structures, stadium canopies, elevated station platforms, and heavy industrial equipment supports, and the same vertical load test methodology is adapted to verify their load-carrying performance in these applications.
FAQ
Why is the bearing tested to a load higher than its rated design load?
The overload factor, typically 1.5 to 2.0 times the design load depending on the governing standard, demonstrates that the bearing possesses an adequate safety margin above its rated capacity. This ensures that unexpected load increases, dynamic effects, or minor installation eccentricities will not lead to sudden failure during the service life of the structure.
Which standards govern this test?
The most commonly applied references are GB/T 17955 for spherical bridge bearings and the EN 1337 series, in particular EN 1337-7 for spherical and cylindrical bearings with PTFE sliding surfaces and EN 1337-2 for sliding elements. Supporting material evaluations may reference ISO and ASTM standards for PTFE compressive and physical properties.
How is vertical deformation evaluated?
Vertical deformation is taken as the average of at least four displacement measurements made around the bearing perimeter. This average must remain within the deformation limit defined by the applicable standard at the design load, must remain stable under the sustained overload, and must not leave a residual deformation beyond the specified tolerance after unloading.
What are the most common failure modes observed in this test?
Typical failures include excessive or nonlinear compression deformation, extrusion or cold flow of the PTFE sheets, local yielding of the steel plates, cracking of welds or castings, non-uniform deformation indicating eccentric loading, and leakage of the internal silicone grease. Each failure mode points to specific design or manufacturing deficiencies that must be corrected.
Can bearings recovered from an existing structure be tested?
Yes. Bearings removed from structures during rehabilitation or replacement can be subjected to vertical load testing, combined with dimensional inspection and sliding surface examination, to assess their remaining capacity and to support decisions on reuse, refurbishment, or replacement.
How long does the test take?
The loading, holding, and unloading sequence for a single specimen is usually completed within one working day, with additional time required for specimen conditioning, instrumentation setup, and post-test visual inspection and reporting. Full test programs covering multiple capacity classes require proportionally longer schedules.
Why Choose ZKGX?
- State-of-the-art analytical equipment
- Highly qualified scientific team
- Fast turnaround time
- Competitive pricing